Mubende District

by February 26, 2017

The access rates in Mubende vary from 5 % in Manyogaseka Sub-County to 83 % in Myanzi Sub-County. Mubende has 957 domestic water points which serve a total of 229,547 people – 229,547 in rural areas. 131 water points have been non-functional for over 5 years and are considered abandoned. Mubende has 2 piped schemes.

Access

30%

Rural Functionality

86%

Equity

397

Management

96%

Gender

67%

Population Density (people/km2) and Population

50 250 1,000 2,000
  100 500 1,500  
MKK Makokoto 123
Makokoto
Population 123
MNY Manyogaseka 56
Manyogaseka
Population 56
KTN Kitenga 117
Kitenga
Population 117
KYN Kiyuni 157
Kiyuni
Population 157
MDD Madudu 167
Madudu
Population 167
MTC Mubende TC 1,765
Mubende TC
Population 1,765
BGZ Bagezza 207
Bagezza
Population 207
KSM Kasambya 129
Kasambya
Population 129
KBL Kibalinga 250
Kibalinga
Population 250
KGN Kigando 112
Kigando
Population 112
NBN Nabingoola 274
Nabingoola
Population 274
BKY Bukuya 197
Bukuya
Population 197
KLW Kalwana 212
Kalwana
Population 212
KSS Kassanda 233
Kassanda
Population 233
KGA Kiganda 189
Kiganda
Population 189
KTM Kitumbi 149
Kitumbi
Population 149
MYN Myanzi 177
Myanzi
Population 177
NLT Nalutuntu 153
Nalutuntu
Population 153
BTL Butoloogo 137
Butoloogo
Population 137

Population figures are projections to the above mentioned date based on UBOS census 2014 and district growth rates. Population density is calculated on land area only. Boundaries reflect the preliminary status only.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 30 %
Rural Access 32 %
Urban Access 0 %

BGZ Bagezza 17 %
Bagezza
Population Served 6,206
BKY Bukuya 40 %
Bukuya
Population Served 13,898
BTL Butoloogo 25 %
Butoloogo
Population Served 12,300
KBL Kibalinga 31 %
Kibalinga
Population Served 12,256
KGA Kiganda NWSC
Kiganda
Population Served NWSC
KGN Kigando 23 %
Kigando
Population Served 10,457
KLW Kalwana 24 %
Kalwana
Population Served 8,942
KSM Kasambya 27 %
Kasambya
Population Served 11,624
KSS Kassanda 63 %
Kassanda
Population Served 30,834
KTM Kitumbi 26 %
Kitumbi
Population Served 16,845
KTN Kitenga NWSC
Kitenga
Population Served NWSC
KYN Kiyuni 60 %
Kiyuni
Population Served 23,400
MDD Madudu 47 %
Madudu
Population Served 18,798
MKK Makokoto 56 %
Makokoto
Population Served 4,906
MNY Manyogaseka 5 %
Manyogaseka
Population Served 624
MTC Mubende TC NWSC
Mubende TC
Population Served NWSC
MYN Myanzi 83 %
Myanzi
Population Served 19,745
NBN Nabingoola 16 %
Nabingoola
Population Served 6,612
NLT Nalutuntu 39 %
Nalutuntu
Population Served 11,936

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Functionality of Point Water Sources

60 % 80 %
70 % 90 %
Rural Functionality 86 %
Urban Functionality Unknown

BGZ Bagezza 100 %
Bagezza
Functional Sources 24
BKY Bukuya 75 %
Bukuya
Functional Sources 46
BTL Butoloogo 93 %
Butoloogo
Functional Sources 42
KBL Kibalinga 86 %
Kibalinga
Functional Sources 37
KGA Kiganda NWSC
Kiganda
Functional Sources 23
KGN Kigando 100 %
Kigando
Functional Sources 50
KLW Kalwana 85 %
Kalwana
Functional Sources 35
KSM Kasambya 74 %
Kasambya
Functional Sources 34
KSS Kassanda 92 %
Kassanda
Functional Sources 136
KTM Kitumbi 75 %
Kitumbi
Functional Sources 52
KTN Kitenga NWSC
Kitenga
Functional Sources 68
KYN Kiyuni 87 %
Kiyuni
Functional Sources 73
MDD Madudu 97 %
Madudu
Functional Sources 70
MKK Makokoto 60 %
Makokoto
Functional Sources 12
MNY Manyogaseka 100 %
Manyogaseka
Functional Sources 6
MTC Mubende TC NWSC
Mubende TC
Functional Sources Unknown
MYN Myanzi 67 %
Myanzi
Functional Sources 50
NBN Nabingoola 96 %
Nabingoola
Functional Sources 24
NLT Nalutuntu 94 %
Nalutuntu
Functional Sources 44

Functionality is the ratio of functional water sources to all water sources. Sources not operating for five or more years are assumed to be abandoned, and hence are not included in the calculation.

People served per technology

Reasons for non-functionality

Type of Management

Source of Funding

District Water Supply Summary

Sub-CountyUrban/
Rural
PopulationPopulation
Served
AccessFunctionalityPoint Water SourcesPiped Water Systems
Protected
springs
Shallow wellsDeep boreholesRainwater
harvesting tanks
DamsValley
tanks
PSP/Kiosk, Tap standsYTHHICNWSC
RUWfPFNFTotFNFTotFNFTotFNFTotFNFTotFNFTotFNFTot
KASSANDA                               
 1 NalutuntuRural30,75911,93639%94%-100%1-114-14223257-73-3---------No
 2 ManyogasekaRural12,7776245%100%-88%------2-24-41126-6------No
 3 MakokotoRural8,8044,90656%60%---8810-101-11-1------------No
 4 MyanziRural23,65619,74583%67%--31428164416319358------------No
 5 KitumbiRural64,30716,84526%75%-100%69152783511-118-8---2-2------No
 6 KalwanaRural37,7028,94224%85%--1-113316729617-11---8-8---No
 7 BukuyaRural34,84313,89840%75%--31423730628628------8311---No
 8 KassandaRural48,57730,83463%92%-100%5164595418-1816117---3-352153---No
 9 KigandaRural41,855NWSCNWSC82%-100%-1141513215617---9-9------Yes
Total 303,280113,97138820921921401644420896121085710674262002068472000No
KASAMBYA                               
 1 KibalingaRural39,56512,25631%86%-100%2-221425122141-1---6-61-1---No
 2 KasambyaRural42,84711,62427%74%-100%-111141515520314---9-9516234--No
 3 NabingoolaRural40,4436,61216%96%-100%3-3181191-12-2---3-3------No
 4 KigandoRural45,71310,45723%100%-100%1-125-259-915-151-15-5------No
 5 BagezzaRural36,8796,20617%100%-100%7-74-412-121-1---3-3------No
Total 205,44747,15523830100213315363063621300012012415000No
BUWEKULA                               
 1 MaduduRural40,24918,79847%97%-100%---5025210-109-91-1---1-1---No
 2 KitengaRural70,020NWSCNWSC93%-100%---164202512627-271-119-19------Yes
 3 ButoloogoRural48,97612,30025%93%--81932234------------2-2---No
 4 KiyuniRural39,25523,40060%87%--153184174817118---------------No
 5 Mubende TCUrban51,697NWSCNWSC---------------------------Yes
Total 250,19768,42127930100344381871920671374560563033303350523400No
District 758,924229,5473086097552681382684501972121811511126729650657758223400No

F = Functional; NF = Non-Functional; Tot = Total; YT = Yard Tap; HH = Household Connections; IC = Institutional Connections

Piped Water Supply Systems

Type of Scheme/GFSNumber of
Schemes
Functionality of SystemType of ManagementWB in place
FunctionalNon-FunctionalPartially FunctionalPrivate OperatorWSCPrivate/IndividualNWSCOtherYesNo
Groundwater based/Not GFS22001100010
Unknown/Not GFS11000000000
Groundwater based/GFS11000100010
Combined Water Based/Not GFS10000001000
Total54000201020

GFS = Gravity Flow Scheme; WB = Water Board; WSC = Water Source Committee