Apac District

by May 24, 2017

The access rates in Apac vary from 55 % in Nambeiso Sub-County to 95 % in Abongomola Sub-County. Apac has 1,186 domestic water points which serve a total of 293,295 people – 272,114 in rural areas. 256 water points have been non-functional for over 5 years and are considered abandoned. Apac has 2 piped schemes.

Access

73%

Rural Functionality

77%

Equity

44

Management

94%

Gender

90%

Population Density (people/km2) and Population

50 250 1,000 2,000
  100 500 1,500  
ATC Apac TC 483
Apac TC
Population 483
CHW Chawente 106
Chawente
Population 106
INM Inomo 187
Inomo
Population 187
CHG Chegere 188
Chegere
Population 188
ADK Aduku 222
Aduku
Population 222
ATL Aduku TC 387
Aduku TC
Population 387
IBJ Ibuje 113
Ibuje
Population 113
NMB Nambeiso 188
Nambeiso
Population 188
APC Apac 155
Apac
Population 155
ABN Abongomola 179
Abongomola
Population 179
AKK Akokoro 67
Akokoro
Population 67

Population figures are projections to the above mentioned date based on UBOS census 2014 and district growth rates. Population density is calculated on land area only. Boundaries reflect the preliminary status only.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 73 %
Rural Access 72 %
Urban Access 88 %

ABN Abongomola 95 %
Abongomola
Population Served 35,437
ADK Aduku 94 %
Aduku
Population Served 29,786
AKK Akokoro 62 %
Akokoro
Population Served 28,386
APC Apac 70 %
Apac
Population Served 40,377
ATC Apac TC NWSC
Apac TC
Population Served NWSC
ATL Aduku TC NWSC
Aduku TC
Population Served NWSC
CHG Chegere 87 %
Chegere
Population Served 34,014
CHW Chawente 60 %
Chawente
Population Served 22,332
IBJ Ibuje 68 %
Ibuje
Population Served 29,685
INM Inomo 71 %
Inomo
Population Served 23,248
NMB Nambeiso 55 %
Nambeiso
Population Served 28,847

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Functionality of Point Water Sources

60 % 80 %
70 % 90 %
Rural Functionality 77 %
Urban Functionality 93 %

ABN Abongomola 74 %
Abongomola
Functional Sources 108
ADK Aduku 86 %
Aduku
Functional Sources 91
AKK Akokoro 77 %
Akokoro
Functional Sources 96
APC Apac 73 %
Apac
Functional Sources 121
ATC Apac TC NWSC
Apac TC
Functional Sources 50
ATL Aduku TC NWSC
Aduku TC
Functional Sources 28
CHG Chegere 77 %
Chegere
Functional Sources 102
CHW Chawente 70 %
Chawente
Functional Sources 67
IBJ Ibuje 95 %
Ibuje
Functional Sources 117
INM Inomo 72 %
Inomo
Functional Sources 62
NMB Nambeiso 73 %
Nambeiso
Functional Sources 88

Functionality is the ratio of functional water sources to all water sources. Sources not operating for five or more years are assumed to be abandoned, and hence are not included in the calculation.

People served per technology

Reasons for non-functionality

Type of Management

Source of Funding

District Water Supply Summary

Sub-CountyUrban/
Rural
PopulationPopulation
Served
AccessFunctionalityPoint Water SourcesPiped Water Systems
Protected
springs
Shallow wellsDeep boreholesRainwater
harvesting tanks
DamsValley
tanks
PSP/Kiosk, Tap standsYTHHICNWSC
RUWfPFNFTotFNFTotFNFTotFNFTotFNFTotFNFTotFNFTot
KWANIA                               
 1 InomoRural32,64223,24871%72%-33%2-29101949857268-11112------No
 2 AdukuRural31,58829,78694%86%-100%1-13073754761516---3-31-1292-9No
 3 AbongomolaRural37,30535,44095%74%--61218468545012626612------------No
 4 Aduku TCUrban8,321NWSCNWSC-97%100%---5-511-11314---1-19-9---Yes
 5 NambeisoRural52,88628,84755%73%-20%1-13-380129242125---145------No
 6 ChawenteRural37,02822,33260%70%-13%------551974121022---178------No
Total 199,770145,82773759735101222932511829958357324577011712191001029209No
MARUZI                               
 1 IbujeRural43,80829,68568%95%--3-31129049422123----221-1---No
 2 AkokoroRural45,67628,38662%77%-67%------761894201131---213------No
 3 Apac TCUrban15,797NWSCNWSC-91%----14216232256-6------718---Yes
 4 ChegereRural38,87534,01487%77%--2132213357157671219------------No
 5 ApacRural57,76240,37770%73%-60%6-6133169519114723301-1224------No
Total 201,918147,4687380915011112501969355484036247109101459819000No
District 401,688293,295737793402113341434418765410676094921861121117281811929209No

F = Functional; NF = Non-Functional; Tot = Total; YT = Yard Tap; HH = Household Connections; IC = Institutional Connections

Piped Water Supply Systems

Type of Scheme/GFSNumber of
Schemes
Functionality of SystemType of ManagementWB in place
FunctionalNon-FunctionalPartially FunctionalPrivate OperatorWSCPrivate/IndividualNWSCOtherYesNo
Unknown/Not GFS22000001000
Groundwater based/Not GFS21100002010
Total43100003010

GFS = Gravity Flow Scheme; WB = Water Board; WSC = Water Source Committee